SEW MOVITOOLS
octoplant supports the management of MOVITOOLS® MotionStudio projects and enables the cyclical monitoring of units that were projected in this development environment.
Image: Integration SEW MOVITOOLS
System compatibility
MOVITOOLS® MotionStudio | 5.6.0: SP1 | 5.72 | 6.0.0.1 | 6.10 | 6.20 | 6.30 | 6.40 | |
---|---|---|---|---|---|---|---|---|
versiondog 3.3.3 | ✓* | ✓* | ✓ | |||||
versiondog 8.1.5 | ✓* | ✓* | ✓ | ✓ | ✓** | ✓** | ✓** |
|
- Upload only
** Upload requires running the service(s) in application mode.
Example for the server:
```"C:Program Files (x86)vdogServerVDogMasterService.exe" /at:s /rd:D:vdServerArchive /app /visibl e```
Example for the agents:
```"C:Program Files (x86)vdogAgentsVDogCompareAgent.exe" /at:s /rd:D:vdAgentArchive /app /visibl e```
```"C:Program Files (x86)vdogAgentsVDogUploadAgent.exe" /at:s /rd:D:vdAgentArchive /app /visibl e```
Other requirements
A licensed version of MOVITOOLS® MotionStudio must be installed on the octoplant server or the computer from which the upload is performed (server or agent).
Devices supported by SEW-EURODRIVE:
MOVIDRIVE (B) MOVITRAC (B) MOVIAXIS MOVIMOT (D) MOVIFIT (Technology, Classic) MOVIGEAR (DSC, DAC, DBC, SNI) DRC (DSC, DAC, DBC, SNI) MOVIPRO (SK, SDC, ADC) MOVI-PLC (basic, advanced) CCU (advanced, power)
Key features and functions
-
Detail comparator for configuration and firmware (version detailed comparison)
-
Automatic detection of program changes (version and backup detailed comparison)
- SmartCompare for MOVITOOLS® MotionStudio projects (version detailed comparison)
- Clear presentation of complete change history
- Component type for MOVITOOLS® MotionStudio projects
- Integrated MOVITOOLS® MotionStudio project tree
- Open the editor directly from
- Upload configuration for MOVITOOLS® MotionStudio
Notes about the comparison
- Device data is compared with the VarData-Interpreter application from MOVITOOLS® MotionStudio.
-
Devices that are solely connected through Networks will not be taken into consideration when comparing the parameters.
-
In addition to the parameters that are excluded by the VarData-Interpreter, octoplant also excludes the following parameters:
8455.0: PA1 setpoin | 9081.0: Debug address |
---|---|
8456.0: PA2 setpoin | 9082.0: Debug address |
8457.0: PA3 setpoin | 9083.0: Debug address |
8458.0: PE1 actual valu | 9084.0: Debug address |
8459.0: PE2 actual valu | 9085.0: Debug Index 1 and |
8460.0: PE3 actual valu | 9086.0: Debug Index 3 and |
8705.0: Sampling tim | 9087.0: Debug Index 5 and |
8706.0: Scope follow-up cycle | 9088.0: Debug Index 7 and |
8707.0: Scope Trigger Sourc | 9089.0: Trigger behaviou |
8708.0: Scope rising edg | 9090.0: Trigger selectio |
8717.0: Scope Debug Address | 9091.0: Trigger sourc |
8718.0: Scope Debug Address | 9092.0: Trigger mod |
8719.0: Scope Debug Address | 9093.0: Analogue trigger leve |
8720.0: Scope Debug Address | 9094.0: Analogue trigger hysteresi |
9095.0: Analogue trigger mas |