KB-126976: Integrating projects

Integrating projects

Integrating existing projects

If a project or a backup version of the device program already exits, proceed as follows:

  1. Create a component in the UserClient. Set your component type as Scalance (which you will find in the Siemens folder).
  2. In Windows Explorer, go to the folder where your SCALANCE project is stored.
  3. Move the project file into the working directory of the component.

Note

To do this, drag and drop the project data onto the component in the project tree.

  1. In the project tree of the UserClient, select the SCALANCE component and click on Create base version and Check-In.

Your SCALANCE project is now integrated into octoplant and can be managed within octoplant.

Integrating projects when no project data is available

If there is no project data available from which a base version could be created, you can still create a component by creating a job. You can then create a base version of the backup on the octoplant server for this job.

To do this, proceed as follows:

  1. Create a component in the UserClient. Set your component type as Scalance (which you will find in the Siemens folder).
  2. In the project tree of the UserClient, select the SCALANCE component and click on Check-In without base version.
  3. Create and execute job.
  4. In the UserClientselect the corresponding component. In the tab Jobs select the backup, click on Copy backup to directory and copy the backup to the working directory.
  5. Create a new version.

Note

You can customize the component type Scalance.


Last update: September 15, 2023

Related Articles

IMPRINT | PRIVACY POLICY | COOKIE POLICY

Privacy Preference Center