KB-127019: Creating jobs

Creating jobs

octoplant allows you to create jobs and to check regularly for any changes made to the data. The purpose of the jobs is to create a backup copy of the configuration.

Note

To execute jobs, the corresponding outgoing and incoming ports on the server, switch and all network devices must be enabled. By default, these are the ports of the SSH connection and the TFTP connection.

The ports through which a connection is established can be changed in the job configuration. When using TFTP, only one switch can be accessed at a time. If it is necessary to backup several switches simultaneously, you will need to set a different TFTP port for each switch and in addition increase the maximum number of parallel uploads in the AdminClient via the menu item INI files.

Creating jobs for Hirschmann Belden switches

  1. Start the AdminClient and open the Jobs module.
  2. In the Project tree, select the Hirschmann Switch component.
  3. In the menu tab, select Create or drag and drop the component into the Jobs section.
  4. Check in the section Job configuration, if the upload type Switches is being displayed.
  5. Make sure the desired settings are in place for the following sections: General, Notification, Upload and compare, Create a version automatically after job run. The Notification and Create a version automatically after job run sections are only displayed if the necessary settings have been implemented.

Note

Under Upload and compare set the compare policy to Backup <-> Previous backup in case no project data in the components was versioned.

  1. Configure the section Switches settings.
    1. In Device, enter the IP address or name of the device that you want the job to access.
    2. Under User, enter the user name under which the device is to be accessed.
    3. In Password, enter the password of the corresponding user.
    4. Under Type, you will see Hirschmann for selection.
    5. For Firmware, select Classic, HiOS, HiSecOS or ONE for the targeted upload of the respective series, or leave the default function Auto. This will automatically detect how the upload should be performed.
    6. In the field Protocol, select the protocol (Telnet or SSH).
    7. In the section Port, enter the outgoing port that you want to connect to the device. The default is 22.
    8. For TFTP Server IP Port, enter the incoming port to receive data from the device. The default is 69.
    9. If you have selected HiOS, HiSecOs or ONE, the text field Name of configuration file will appear. Here, enter the name under which you want the configuration file to be saved.
  2. Save the job and execute it.

Note

The file specification and compare settings only apply to the job that they were made for. The comparator settings can

be applied to other Jobs in the Jobs list by using drag-and-drop.