KB-127385: File UploadAgentStation.ini

File UploadAgentStation.ini

[Common]

Key Description Value Default value

4900 Specifies the maximum number of uploads that can be performed parallel.<1... 1024>5

4902

Specifies how to handle files relevant to an upload (Archive.zip and Backup.zip) after an upload has been completed.

0: The Archive.zip and Backup.zip files are not deleted and may be used for further uploads.

1: The Backup.zip file will be deleted.

0 or 1 1

H1ExclusiveUse

Shows whether the H1 driver is used exclusively.

If PC-H1-PLC is selected as an access path, the upload may hang under certain circumstances. One solution would be to allow only one H1 connection.

Y, N N

[ABBFreelance]

Key Description Value Default value

5311 Specifies the full path to the ABB Freelance installation directory.<Path>Path to the registered COM server CBF.Application

5310 Specifies the ID used by the PC, from which the upload is performed, and logs onto the resources.<1... 255>21

[AtlasCopcoTighteningSystems]

Key Description Value Default value

5011 Specifies the fully qualified path to the ttpf.exe tool from Atlas Copco.<Path to tool>No path

[GEProficyMachineEdition]

Key Description Value Default value

36870

Specifies whether events, errors and warnings are logged to a file during upload.

The file will be created under the name GE_PME_Upload.log in theoctoplant temporary folder.

Y, N N

[Kistler]

Key Description Value Default value

36387 Specifies the location of the tool Sicherungstool.exe from Kistler for the MF-P series.<Path to tool> ThirdPartyKistler

[Lenze840DProtec]

Key Description Value Default value

5340 Specifies the full path to the L-Force Engineer installation directory.<Path>No path

[SickSensors]

Key Description Value Default value

5470 Specifies the fully qualified path to the directory with the SDD files (device description files).<Path> <ProgramData>SICKSOPASjarsdevices

[SimaticS5]

Key Description Value Default value

5050 Specifies the network adapter to which the INAT H1 protocol is bound when uploading using H1.<0... 128>0

5052 Specifies the number of the serial COM port to be used for the upload via AS511 protocol.<1... 255>1

5053

Specifies the path to the program PLC-VCOM.EXE from Process-Informatik.

This program is needed for uploading via S5 LAN++. If the path was not configured in the INI file, the octoplant system will try to determine it automatically.

< Path to PLCVCOM. EXE (without file name)>No path

[SimaticS7]

Key Description Value Default value

5090 Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. 0 … 128 0

5091

Enter access point for SIMATIC NET.

This access point needs to be configured beforehand in SIMATIC NET.

<Name of access point>S7ONLINE

5092

Specifies whether F blocks are also to be copied from the program of the controller when the program is copied to a PC using the UserClient.

If F blocks are not copied, a message will be displayed.