KB-127178: Changing the comparator configuration

Changing the comparator configuration

The MOTOMAN project file System.sys has a timestamp that is recognized as a difference by octoplant. To avoid this, you must change the comparator configuration of the project file System.sys to exclude the line with the timestamp.

Proceed as follows:

  1. In the UserClient, select your MOTOMAN-NX100 component then press Alt+Enter or right-click on the component then select Edit component configuration.
  2. Select the option Comparator configuration.

  3. Image: Dialog Create new component, button Comparator configuration

  4. In the tab, search for the file SYSTEM.SYS. This is located under Comparison configuration.

  5. Image: Dialog Comparison configuration

  6. In the field Exclude lines from comparison, proceed as follows:

    1. Enter TOTAL: 2???/??/?? ??:??,?????:??’??Motoman_NX100_UC_Compare_config_02.pngImage: Dialog Configure comparison, exclude lines from comparison
    2. Click on OK.
  7. Click on Apply.Motoman_NX100_UC_Apply_Component_settings.pngImage: Dialog Create component, button Apply
  8. Create a new version and check it in.

Last update: September 15, 2023