Upload and Compare
Depending on the job configuration the following data will be saved during job execution:
Copy disaster recovery dat | |||
---|---|---|---|
Content | Memor | Compariso | Nam |
Complete copy of the SRA | SRA | N | SRAM_BAK.00 |
PMC sequence progra | FRO | Yes (SmartCompare | PMCx, x=1,2,3,4,5, |
PMC message fil | FRO | Yes (binary | MxPMCMSG, x=1,2,3,4, |
I/O configuration dat | FRO | Yes (binary | IOCON |
C language executer application dat | FRO | Yes (binary | CEX_nn |
C language executer user dat | FRO | Yes (binary | CEXnxxx |
Macro executer application dat | FRO | Yes (binary | PDnnxxx |
FANUC picture project (compiled | FRO | Yes (binary | FPF 2.0M or FPF |
NC programs in binary representatio | FRO | Yes (binary | ATA PRO |
Maintenance data (spare part number, software packages, that are installed on the CNC. | FRO | Yes (binary | MAINTIN |
Other file | FRO | Yes (binary | |
Copy PMC dat | |||
PMC parameter | SRA | Yes (ASCII | PMCx_PRM.TXT, x=1,2,3,4,5, |
PMC sequence progra | FRO | Yes (SmartCompare | PMCx, x=1,2,3,4,5, |
PMC message fil | FRO | Yes (binary | MxPMCMSG, x=1,2,3,4, |
I/O configuration dat | FRO | Yes (binary | IOCON |
Copy CNC dat | |||
NC program | SRA | Yes (ASCII | PROGRAM_MEMORYCNC_MEMMTB1AB |
Tool offset dat | SRA | N | TOOLOFST.TX |
CNC parameter | SRA | Yes (ASCII | CNC-PARA.TX |
Pitch error compensation dat | SRA | N | PITCH.TX |
Custom macro variable | SRA | Yes (ASCII | MACRO.TX |
Work zero offset dat | SRA | Yes (ASCII | EXT_WKZ.TX |
Operation history dat | SRA | N | OPRT_HIS.TX |
Rotary table dynamic fixture offse | SRA | Yes (ASCII | FIXTURE.TX |
Copy all user data from the FRO | |||
Other files!!! note Also contains SRAM backups (automatic data backup) | FRO | Yes (binary |
Note
Please note:
- For some of the supported devices not all these data are available and retrievable. Due to the machine configuration, non-retrievable files can only be backed up manually.
- If a PMC program was changed on the controller without a backup being stored in the FROM, a warning will be shown during upload.
- During comparison the path configured in the LAD/PMC files (PMCx, x=1,2,3,4,5,S) will be used as the pathway to the file instead of the file name.
- During a version comparison only LAD files are compared.
Last update: September 15, 2023