Creating jobs
Note:
- For WinCC flexible, there is no specific upload type.
- The upload of engineering station data (creating backups through a machine network) can be executed in versiondog using a UNC job or a local job. The prerequisite for this is that the runtime of the HMI is terminated beforehand. If you use the backup tool Prosave, which is delivered with TIA Portal, shut down the Panel PCs before the upload.
- Panel PC’s can only be backed up to a limited extent. You can save the backup on a defined network share.
- Data can be imported to or exported from a network share using panels. versiondog can then back up the data with an UNC job.
Creating a UNC job for SIMATIC WinCC flexible
Note
If the WinCC flexible editor is not installed on the computer, on which the comparison is to take place, a **Compare
Agent** will be required.
Creating a local job for SIMATIC WinCC flexible
Follow the steps described here for the upload type local directory.
Related Topics
- AdminClient -> INI files
- AdminClient -> Job configuration upload type UNC (UNC-Jobs)
- AdminClient -> Job configuration Upload type local directory (local Jobs)
Last update: September 15, 2023