Configuring the IPC
The following section demonstrates how you can configure**TwinCAT V2.x with TwinCAT System Control on the IPC on which you want to carry out an upload. You will require a remote connection** between the IPC and the versiondog server.
- Start TwinCAT System Control.
- Right-click on the AMS Router icon.
- Record the AMS Net ID of the local computer (you need this for Job configuration).
- In the Remote computer dialog, click on Add.
- Enter the data in the following fields:Name: Choose a descriptive name for the connection (for example, versiondog + device name).AMS Net ID: Enter the AMS Net ID that you entered in your Agentstation.ini file.IP address:Â Enter the IP address of the computer on which the versiondog server is running OR the computer on which the agent is installed.Transport: In the dropdown menu, select TCP/IP and click on OK.
- Close the application and restart the computer, so that the changes are recognized by the TwinCAT runtime.
- Start upthe TwinCAT PLC Control.
- Go to Online and select Choose runtime system.
- Check whether the connection to versiondog is listed here.
- Note down the runtime number. You need this number for Job configuration.
- Repeat these steps for each TwinCAT device.