File UploadAgentStation.ini
[Common]
Key Description Value Default value
4900 Specifies the maximum number of uploads that can be performed parallel.<1... 1024>
5
4902
Specifies how to handle files relevant to an upload (Archive.zip and Backup.zip) after an upload has been completed.
0: The Archive.zip and Backup.zip files are not deleted and may be used for further uploads.
1: The Backup.zip file will be deleted.
0 or 1 1
H1ExclusiveUse
Shows whether the H1 driver is used exclusively.
If PC-H1-PLC is selected as an access path, the upload may hang under certain circumstances. One solution would be to allow only one H1 connection.
Y, N N
[ABBFreelance]
Key Description Value Default value
5311 Specifies the full path to the ABB Freelance installation directory.<Path>
Path to the registered COM server CBF.Application
5310 Specifies the ID used by the PC, from which the upload is performed, and logs onto the resources.<1... 255>
21
[AtlasCopcoTighteningSystems]
Key Description Value Default value
5011 Specifies the fully qualified path to the ttpf.exe tool from Atlas Copco.<Path to tool>
No path
[GEProficyMachineEdition]
Key Description Value Default value
36870
Specifies whether events, errors and warnings are logged to a file during upload.
The file will be created under the name GE_PME_Upload.log in theversiondog temporary folder.
Y, N N
[Kistler]
Key Description Value Default value
36387 Specifies the location of the tool Sicherungstool.exe from Kistler for the MF-P series.<Path to tool>
ThirdPartyKistler
[Lenze840DProtec]
Key Description Value Default value
5340 Specifies the full path to the L-Force Engineer installation directory.<Path>
No path
[SickSensors]
Key Description Value Default value
5470 Specifies the fully qualified path to the directory with the SDD files (device description files).<Path>
<ProgramData>
SICKSOPASjarsdevices
[SimaticS5]
Key Description Value Default value
5050 Specifies the network adapter to which the INAT H1 protocol is bound when uploading using H1.<0... 128>
0
5052 Specifies the number of the serial COM port to be used for the upload via AS511 protocol.<1... 255>
1
5053
Specifies the path to the program PLC-VCOM.EXE from Process-Informatik.
This program is needed for uploading via S5 LAN++. If the path was not configured in the INI file, the versiondog system will try to determine it automatically.
< Path to PLCVCOM. EXE (without file name)>
No path
[SimaticS7]
Key Description Value Default value
5090 Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. 0 … 128 0
5091
Enter access point for SIMATIC NET.
This access point needs to be configured beforehand in SIMATIC NET.
<Name of access point>
S7ONLINE
5092
Specifies whether F blocks are also to be copied from the program of the controller when the program is copied to a PC using the UserClient.
If F blocks are not copied, a message will be displayed.
Y/N N