KB-133419: Creating jobs

Creating jobs

  1. Start the AdminClient and open the Jobs module.
  2. In the project tree, select a Sinumerik ONE component.
  3. In the menu tab, click on Create or drag and drop the components into the Jobs section.
  4. Check in the section Job configuration, if the upload type SINUMERIK ONE is being displayed.
  5. Make sure the desired settings are in place for the following sections: General, Notification, Upload and compare, Create a version automatically after job run. The sections Notification and Create a version automatically after job run will only be displayed if the necessary settings have been implemented.If no project data has been versioned in the component, select under Upload and compare**Previous backup <-> Backup. This is located under Compare policy**. !!! note If problems occur whilst running the plugin, the upload may fail. If this occurs, in the General section of the Job execution by schedule, use the On error: setting to specify when and how often the job execution should be repeated.

  6. Configure the section SINUMERIK ONE settings.

    1. Sinumerik_ONE_Jobconfig_Settings.PNG
    2. In the section Name of the archive, enter the name of the archive that you want to be created by the job. The file ending of the archive has to be .dsf. If there is a version of the archive in the component, that you want to be compared with the job result, both archives must have the same name. A serial commissioning archive (SIBN archive) in DSF format (Data Storge Folder) is always created during job execution.
    3. In the field Device, enter the name or the IP address of the controller that you wish to execute the job for.
    4. In the field Port, enter the port that you want versiondog to use to communicate with the plug-in. This must match the plugin port.
    5. In the drop-down menu Archive type, you can select whether all data from this machne or if the data macine series is to be saved.
  7. Configure the Backup section: 1. Sinumerik_ONE_Jobconfig_Backup.PNG 1. Select the appropriate checkbox to decide which data you want to be saved in the DSF archive. !!! note The checkbox PLC is greyed out by default and cannot be activated as creating a backup forces the PLC into stop mode. Here, it is a behaviour of the device over which versiondog currently has no influence.

  8. In the section Backup conditions, you can introduce the requirement that backups can only be created if certain requirements have been fulfilled.

    1. Sinumerik_ONE_Jobconfig_Backup_Conditions.PNG
    2. Activate All channels in reset so that a warning is displayed in the job results, if not all channels were reset during job execution.
    3. Activate No tools in spindle so that a warning is issued in the job results if a tool was in the spindle during job execution.
  9. Configure the section File specifications and compare settings.
    1. Sinumerik_ONE_Jobconfig_File_specifications.PNG
  10. Here, you can adjust the comparison for the job.
    1. Activate the Enable custom configuration for this job checkbox.
    2. Click on Edit.
    3. The dialog Settings for backup files will then open.
      1. Sinumerik_ONE_Dialog_Backup_files.PNG
  11. Save the job and execute it.

Note

The file specification and compare settings only apply to the job that they were made for. The comparator settings can

be applied to other jobs in the Jobs list by using drag-and- drop.


Last update: September 15, 2023