Key Description Value Default value

17725 Specifies whether an upgrade directory is created during change validation. Y, N N

17726

Specifies whether PLV.PKG are ignored in the comparison.

Depending on your workflow, the version and backup comparison of PLC.PKG may always show a difference. This is because versiondog only compares the timestamps.

Y, N N

[CognexSensors]

Key Description Value Default value

38530 Specifies whether differences are displayed in plain text after a comparison. Y, N N

[SimaticS7]

Key Description Value Default value

7006 Indicates which versions of the SIMATIC S7 Manager are released.<Versions separated by a comma> 5.1,5.2,5.3,5.4,5.5,5.6

7165 Specifies whether data blocks are checked only for length and structure, or whether they are also checked for content and properties during a backup comparison. Y, N Y

7166

Specifies whether data blocks are checked only for length and structure, or whether they are also checked for content and properties during a version comparison.

Y, N Y

7167 Specifies whether CFC files are compared according to content or name. Y, N N

7169 Specifies whether PLV.PKG are included in the comparison. Y, N N

36802 Specifies whether to compare all blocks or only the blocks in the standard library that were not produced using the SCL Compiler. Y, N N